External Reference Parameters
484
FQ2-S/CH User’s Manual
161
Judge-
ment
condi-
tions
Judgement lower limit
for search coordinate X
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
162
Judgement upper limit
for search coordinate Y
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
163
Judgement lower limit
for search coordinate Y
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
164
Judgement upper limit
for search angle
Set / Get
−
180 to 180
180
---
Judgement
condition
165
Judgement lower limit
for search angle
Set / Get
−
180 to 180
−
180
---
Judgement
condition
166
Judgement upper limit
for correlation
Set / Get 0 to 100
100
---
Judgement
condition
167
Judgement lower limit
for correlation
Set / Get 0 to 100
60
---
Judgement
condition
168
Position compensation
X upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
169
Position compensation
X lower limit
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
170
Position compensation
Y upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
171
Position compensation
Y lower limit
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
172
Theta position compen-
sation upper limit
Set / Get
−
180 to 180
180
---
Judgement
condition
173
Theta position compen-
sation lower limit
Set / Get
−
180 to 180
−
180
---
Judgement
condition
174
Judge
con-
dit6ion
Disp. Image Selection
Set / Get 0: Measurement image
1: Meas. Img.+Model Img.
2: Edge Image
3: Edge Img.+ Model Img.
1
---
---
178
Edge Level
Set / Get 0: No
1: Yes
1
---
---
179
Mask Size
Set / Get
0: 3
×
3
1: 5
×
5
2: 7
×
7
0
---
---
182
Edge Level Auto
Set / Get 0: OFF
1: ON
1
---
---
184
Acceptable Dist. Level
Set / Get
0: Low
1: Medium
2: High
2
---
---
185
Noise Removal Level
Set / Get 0 to 100
0
---
---
Exter-
nal ref-
erence
number
Category
Data name
Set / Get
Data range
Default
Expression
text string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......