Reading 2D-codes
FQ2-S/CH User’s Manual
195
4
Setting Up Inspect
ions
9
Press [Back].
[Item ref.]: Select this item to use the immediately preceding read results as the verification character
string. The following inspection items can be used as references: Bar code, 2D-code, 2D-
code (DPM), and OCR. You cannot reference an inspection item at an item number that is
after the item number of the inspection item that you are editing. When you register a char-
acter string from the master data, the item number of the inspection item that is being refer-
enced, such as “Ref. 00,” will be displayed.
Using Item References: p. 148
5
Repeat the above procedure to register more than one character string in the master data.
6
Press [Back] to return to the verification conditions screen.
7
Press [Verif. master data] and select the character string in the master data to use for verification.
8
Set the following verification conditions as required.
Setup Item
Setting Value
Description
Verif. master data
OFF (Default)
Sets whether to verify the character string that was read from the
barcode against a character string that is registered in the master
data. To verify the read character string against the master data,
select the character string to use for verification.
All master data
Master data 0 to 31
Partial verif. on/off
No (Default)
The number of digits in the read results to be verified with the mas-
ter data can be limited. When [Partial verification] is set to [Yes], set
the first and last compared digit positions. Up to 32 characters can
be set as the number of digits.
Example: First compared digit 2, last compared digit 6
The text string used for verification becomes "MRON2".
Manually register “MRON2”, the comparison
character string, in master data registration.
Yes
Partial verif. setup
1 to 1024
(Default value
first digit:1 last digit:1024)
Master data regist.
---
Registers a character string in the master data.
When you specify the vitrification range, adjust the data manually
after executing the master data automatically.
External teach No.
OFF (Default)
Sets the character string in which to automatically register the read
result for teaching from an external device.
Master data 0 to 31
O M R O N 2 0 0 8
2nd digit
6th digit
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......