Reading 2D Codes (DPM)
FQ2-S/CH User’s Manual
203
4
Setting Up Inspect
ions
Step 2
Teaching
For teaching, the region to measure and the 2D code within that region are set as read conditions. You can
also register the contents that was read from the 2D code as a verification condition in the master data.
Step 4 Setting the Verification Conditions: p. 207
[Inspect] - [Inspection] - [Add item.] - [2D-code (DPM)] - [Settings] Tab Page
1
Press [Teach].
2
Display the image of the 2D code.
3
Move the rectangle so that it surrounds the 2D
code.
4
Press the [OK] Button.
5
Press [TEACH] on the lower right of the display.
6
The result of reading the 2D code that was displayed will be displayed along with a confirmation
dialog box for registration in the master data.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......