Inspecting with the Edge Pitch Inspection Item
FQ2-S/CH User’s Manual
289
4
Setting Up Inspect
ions
Step 2
Teaching
Teaching means to store the region as reference data for the measurement.
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Edge Pitch]
−
[Settings] Tab Page
Step 3
Adjusting the Judgment Parameters
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Edge Pitch]
−
[Settings] Tab Page
1
Press [Teach].
2
Place the object that is to be used as the mea-
surement reference in front of the camera.
3
Move the rectangle to the location to be mea-
sured.
4
Press [OK].
Changing the Measurement Region: p.
227
1
Press [Judgement].
2
Press the parameters and set the range that is to be
judged as OK.
Continuous measurements will be performed for the im-
ages that are displayed. The measured value is dis-
played beside the parameter name.
3
Press [OK] to enter the value.
The middle arrow is the direction
for detecting an edge.
Moves the end point of
the measurement region.
Changes the width
of the measure-
ment region.
Moves the starting
point of the
measurement region.
Drag to move
the region.
Blue for OK. Red for NG.
Upper limit
Lower limit
You can change the parameters for judgment conditions on the
Display Settings Display.
Press
[ ]
−
[Display setting] on the right of the display to switch
to the Display Settings Display.
Note
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......