Inspecting with the Area Inspection Item
304
FQ2-S/CH User’s Manual
Reflect in Total Judgment
You can specify whether to reflect the judgment results of an inspection item in the overall judgment.
(The Default is to reflect them.)
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Area]
−
[Details] Tab Page
−
[Output parameter]
Unstable Area Results
The Desired Color Cannot Be Detected
Add a specific color or enlarge the color range.
• You can change the output form for each measurement value to one of the following settings.
Press
[ ]
−
[Result type] on the right of the display.
Absolute value (Default): The measured coordinates are output.
Relative value: The difference from the reference position is output as coordinates.
Ratio: The percentage of the reference value is output. (This applies to the area only.)
Note