Menu Tables
452
FQ2-S/CH User’s Manual
In
spect
ion
Se
tt
ings
Jud
gemen
t
(L
abeli
ng*
2
)
Number of labels
Set the upper and lower limits of the
number of labels for an OK judgement.
0 to 100
(Defaults: Upper limit: 100
Lower limit: 0)
Scene
Total label area
Set the upper and lower limits of the
total label area for an OK judgement.
0 to 999,999,999.9999
(Defaults: upper limit: 999,999,999.999
lower limit: 0)
Scene
Area
Sets the upper and lower limits of the
area for an OK judgement.
0 to 999,999,999.9999
(Defaults: upper limit: 999,999,999.999
lower limit: 0)
Scene
Gravity X
Set the upper and lower limits of the
gravity X for an OK judgement.
−
99,999.9999 to 99,999.9999
(Defaults: upper limit: 99,999.9999
lower limit:
−
99,999.9999)
Scene
Gravity Y
Set the upper and lower limits of the
gravity Y for an OK judgement.
−
99,999.9999 to 99,999.9999
(Defaults: upper limit: 99,999.9999
lower limit:
−
99,999.9999)
Scene
Master angle
Sets the upper and lower limits of the
master angle for an OK judgement.
−
180 to 180
(Defaults: upper limit: 180
lower limit:
−
180)
Scene
Result type
(Except for
OCR, 2D-code
(DPM), Edge
Pitch, and Label-
ing)
You can change the output form of the
measurement values.
Absolute value (Default)
Relative value
Ratio (Edge Position or Area only)
Scene
p. 218
p. 234
p. 262
p. 274
p. 284
p. 303
Display setting
You can change the parameters of the
judgment conditions.
The names of the judgment conditions
are displayed.
Scene
p. 218
p. 234
p. 262
p. 274
p. 284
p. 303
Auto
adjustment
(Except for
Labeling and
Edge Pitch)
Automatically adjusts the judgment
parameters by using actual work-
pieces which are considered as good
or faulty products.
OK Teach
NG Teach
Scene
Judgment Mode
(Only for OCR)
Select the Judgment mode.
All (Default)
Individual
Scene
Verif. master
data
Sets whether to verify the read charac-
ter string against a character string
that is registered in the master data.
Sets the character string to use to ver-
ify the read character string against
the master data.
OFF (Default)
Master data 0 to 31
Scene
Menu command
Description
Setting range
Data
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...