Inspecting with the Shape Search III Inspection Item
234
FQ2-S/CH User’s Manual
Step 3
Adjusting Judgment Parameters
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Shape Search]
−
[Settings] Tab Page
1
Press [Judgement].
2
Press each parameter and set the range that is to be
judged as OK. Set the range for each of the following
parameters.
Continuous measurements will be performed for the im-
ages that are taken.
You can change the parameters for judgement conditions on the Display Settings Display.
Press
[
]
−
[Display setting] on the right of the display to switch to the Display Settings Display.
3
Press [OK] to accept the value.
4
Press [Back] to end making the setting.
Parameter
Setting
Description
Correlation
Range : 0 to 100
Defaults: Lower: 60
Upper: 100
Adjust the upper and lower limits of the correlation for
an OK judgment.
When the candidate level is higher than the judgment
lower-limit value of correlation, the candidate level has
priority.
If the correlation value is lower than the candidate level,
the measurement result is 0.
Position X
Range :
−
99,999.9999 to 99,999.9999
Defaults : Lower:
−
99,999.9999
Upper: 99,999.9999
Adjust the upper and lower limits of measurement posi-
tion X for an OK judgment.
Position Y
Range :
−
99,999.9999 to 99,999.9999
Defaults : Lower:
−
99,999.9999
Upper: 99,999.9999
Adjust the upper and lower limits of measurement posi-
tion Y for an OK judgment.
Angle
Range:
−
180 to 180
Defaults: Lower:
−
180
Upper: 180
Adjust the upper and lower limits of angle for an OK
judgment.
Count
Range : 0 to 32
Defaults: Lower: 0
Upper: 32
Adjust the upper and lower limits of the detection count
for an OK judgment.
Blue for OK. Red for NG.
Upper limit
Lower limit
If more than one result was detected, you
can switch to a display for each result.
(Multi-point output must be enabled.)
Note
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......