Inspecting with the Shape Search III Inspection Item
FQ2-S/CH User’s Manual
233
4
Setting Up Inspect
ions
The following settings can be changed from the menus in the lower-right of the screen.
• [Model region]:
Editing the Model and Measurement Regions p.224.
[Insp. region] :
Changing the Measurement Region p. 227
[Detection point]:
Changing Output Coordinate Positions p.228
[Edge extraction]:
When Edge cannot be detected at model region p.241
[Display setting]: the following images can be selected.
Measurement image: displays the Measurement image.
Measurement
image
+
Model image (Default): displays the detected Model on the Edge image.
Edge image: displays the Edge image.
Edge image
+
Model image: displays the detected Model on the Edge image.
Green: Model points matching with Edge image.
Yellow: Model points match with Edge image except for direction.
Red: Model points not matching with Edge image.
Note