Inspecting with the Area Inspection Item
FQ2-S/CH User’s Manual
305
4
Setting Up Inspect
ions
Extraction Is Automatically Performed for an Undesired Color When Teaching
Manually set the color for which to measure the area.
[Inspect]
−
[Inspection]
−
[Area]
−
[Modify]
−
[Settings] Tab Page
−
[Teach]
• Sensors with Color Cameras Only
1
Press [ ]
−
[Set color] on the right of the dis-
play.
2
Drag around the color for which you want to
measure the area.
Areas with that color will be automatically detected.
Continuous measurements will be performed for
the images that are displayed.
Only the extracted color will appear on the display.
3
Press [OK].
4
Press [TEACH].
5
Press [Back] to end teaching.