Reading with OCR
158
FQ2-S/CH User’s Manual
・
Executing Teach function, parameters are set automatically
The following parameters in measurement parameters, are automatically set by executing Teach function.
Limiting Readable Characters
Limiting the readable characters decreases the possibility of mis-reading similar characters.
[Inspect]
−
[Inspection]
−
[OCR]
−
[Details] Tab Page
−−
[Dictionary parameter]
−−
[Individual char.]
Changing the Output Code for Errors (Default: NG)
You can change the character string that is output for read errors.
(The output code must be no more than 20 characters.)
[Inspect]
−
[Inspection]
−
[OCR]
−
[Details] Tab Page
−
[Output parameter]
−
[Error string]
Troubleshooting Unstable Read Results
• The read results may be unstable if the contrast is low. Adjust the brightness to improve the contrast.
• Set a custom dictionary.
• Adjust the detailed parameters.
When reading a variable length string
Set the Read Length of measurement parameters to Variable.
Then set the character format to the maximum character string format.
Parameter
Setting
Parameter
Setting
Character color
Manual
Rotation compensation
Auto
Printing type
Manual
Slant compensation
Auto
Dot ver. interval
Auto
Max Width Setting
Auto
Dot ver. interval
Auto
Max Width
Auto
Char.thick.th.
Auto
Max Height
Auto
Boundary correction
Auto
Min Height
Auto
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......