External Reference Parameters
494
FQ2-S/CH User’s Manual
183
Judge-
ment
condi-
tions
Edge position Y lower
limit 0
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
185
Edge position X upper
limit 1
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
186
Edge position X lower
limit 1
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
187
Edge position Y upper
limit 1
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
188
Edge position Y lower
limit 1
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
190
Position compensation
X upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
191
Position compensation
X lower limit
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
192
Position compensation
Y upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
193
Position compensation
Y lower limit
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
310
Logging
condi-
tions
Data logging switch for
entire unit
Set / Get
0: Data logging OFF
1: Data logging ON
0
---
---
311
Data logging switch for
judgement
Set / Get
0: Data logging OFF
1: Data logging ON
0
---
---
312
Data logging switch for
scroll X
Set / Get
0: Data logging OFF
1: Data logging ON
0
---
---
313
Data logging switch for
scroll Y
Set / Get
0: Data logging OFF
1: Data logging ON
0
---
---
314
Data logging switch
for detected edge posi-
tion X0
Set / Get
0: Data logging OFF
1: Data logging ON
0
---
---
315
Logging
condi-
tions
Data logging switch
for detected edge posi-
tion Y0
Set / Get
0: Data logging OFF
1: Data logging ON
0
---
---
316
Data logging switch
for detected edge posi-
tion X1
Set / Get
0: Data logging OFF
1: Data logging ON
0
---
---
317
Data logging switch
for detected edge posi-
tion Y1
Set / Get
0: Data logging OFF,
1: Data logging ON
0
---
---
700
Display
settings
Position compensation
X display
Set / Get
0: ON
1: OFF
0
---
---
701
Position compensation
Y display
Set / Get
0: ON
1: OFF
0
---
---
702
Detected edge position
X0 display
Set / Get
0: ON
1: OFF
0
---
---
703
Detected edge position
Y0 display
Set / Get
0: ON
1: OFF
0
---
---
704
Display
settings
Detected edge position
X1 display
Set / Get
0: ON
1: OFF
0
---
---
705
Detected edge position
Y1 display
Set / Get
0: ON
1: OFF
0
---
---
External
refer-
ence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......