Wiring
FQ2-S/CH User’s Manual
59
2
Install
ation an
d
C
onn
ecti
ons
RS-232C Interface Sensor Data Unit (FQ-SDU2
)
For the I/O connector harness, use an FQ-VP2
Parallel Cable for the FQ-SDU2 or a MIL-standard
harness, such as the OMRON XZ2F. (The Cables are sold separately.)
Pins 1 to 16 and pins 17 to 32 are for separate connectors. One FQ-VP2
is required for each connector.
Signal
Application
Power supply (24 V)
These terminals are for the external power supply (24 V).
• Wire the power supply separately from other devices. If the wiring for other devices is
placed together or in the same duct as the wiring for the Sensor, the influence of elec-
tromagnetic induction may cause the Sensor to malfunction or may damage it.
• Do not allow the load current to exceed 50 mA. The output circuit may be damaged if
the load current exceeds 50 mA.
Power supply (0 V)
Frame ground
This is the frame ground terminal.
Connect the ground wire by a D-type ground (ground resistance of 100
Ω
or less).
FQ2-S3
@@@@@
-
@@@
FQ2-S4
@@@@@
-
@@@
FQ2-CH1
@@@@@
-M
(Sensors with Built-in Lighting or Sensors with
C-mounts)
Power supply (24 V)
Power supply (0 V)
Frame ground
RS-232C connector
1 2 17
18
3 4 19
20
5 6 21
22
7 8 23
24
9 10 25 26
11 12 27 28
13 14 29 30
15 16 31 32
(Screw size: M3,
Tightening torque:
0.54 N·m)
FQ-WU0
Sensor Data Unit Cable
Important
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......