Adjusting the Images That Were Taken
110
FQ2-S/CH User’s Manual
• Interpolation
Select the image to reflect the results of Interpolation processing to.
If you select [Bilinear], the precision of position compensation will increase.
[Image]
−
[Image adjustment]
−
[Search position comp.]
−
[Modify]
−
[Details]
−
[Scroll parameter]
−
[Interpolation]
1
Press [Details]
−
[Scroll parameter]
−
[Interpolation]
2
Set the interpolation to [Bilinear] or [None].
• Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via Ethernet or used in
calculations.
Parameter
Setting
Description
Interpolation
Bilinear
Connects the points with a line and calculates an approximate
value,
Although, the processing time will be longer, a smooth image can
be acquired when you select [Bilinear],
None (Default)
Position compensation is performed at the pixel level.
Expression
text string
Data name
Description
Data range
JG
Judgement
-2: No judgement (not measured)
0: Judgement is OK
-1: Judgement is NG
-10: Image error
-15: Out of range error
This is the judgment result.
DX
Scroll X
-99,999.9999 to 99,999.9999
This is the amount of position
compensation for the X coordinate.
DY
Scroll Y
-99,999.9999 to 99,999.9999
This is the amount of position
compensation for the Y coordinate.
X
Position X
-99,999.9999 to 99,999.9999
This is the X coordinate of the position
where the model was found.
Y
Position Y
-99,999.9999 to 99,999.9999
This is the Y coordinate of the position
where the model was found.
SX
Reference X
-99,999.9999 to 99,999.9999
This is the X coordinate of the position
where the model was registered.
SY
Reference Y
-99,999.9999 to 99,999.9999
This is the Y coordinate of the position
where the model was registered.
CR
Correlation
0 to 100
This is the correlation.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......