Calibration
FQ2-S/CH User’s Manual
377
7
Conven
ien
t Fu
ncti
ons
Parameter
With this method, you directly enter values to set calibration.
The calibration parameters will be automatically calculated when you enter the following three parameters.
Parameter
Setting
Description
Coordinate
(coordinate system)
• Righthand
• Lefthand (Default)
Lefthand: The positive direction is clockwise when coordinates are
specified.
Righthand: The positive direction is counterclockwise when coordi-
nates are specified.
Origin
• Upperleft (Default)
• Lowerleft
• Center
Select the location of the origin of the coordinate system.
Magnification
0.0001 to 9.9999
Default: 1.0000
Set the actual dimension that corresponds to one pixel.
Lefthand
Coordinate
System
Positive direction
Positive direction
Righthand
Coordinate
System
0
0
X
X
Y
Y
Upper left
Center
Lower left