
External Reference Parameters
536
FQ2-S/CH User’s Manual
Edge Width (FQ2-S1/S2/S3 series or FQ2-S4 series only)
External
refer-
ence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result
Judgement
Get only
−
2: No judgement (not measured),
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
−
2
JG
---
5
Edge width
Get only
0 to 99,999.9999
0
W
Logged data
6
Reference edge width
Get only
0 to 99,999.9999
0
SW
Logged data
7
Difference in edge
width
Get only
0 to 99,999.9999
0
DF
Logged data
103
Output
parame-
ter
Reflect
Set / Get
0: Yes
1: No
0
---
---
120
Mea-
sure-
ment
condi-
tions
Edge level specification
method
Set / Get
0:%
1: Absolute value
0
---
---
121
Set color Set color
Set / Get
Edge color specification
0: Not specified,
1: Specified
0
---
---
122
Mea-
sure-
ment
condi-
tions
Measurement method
Set / Get
0: Projection
1: Differentiation
0
---
---
131
Edge color red
Set / Get
0 to 255
255
---
---
132
Edge color green
Set / Get
0 to 255
255
---
---
133
Edge color blue
Set / Get
0 to 255
255
---
---
137
Edge level
Set / Get
0 to 100
50
---
---
138
Edge level absolute
value
Set / Get
0 to 442
20
---
---
139
Noise level
Set / Get
5 to 442
5
---
---
142
Density change
Set / Get
0: Light to Dark
1: Dark to Light
0
---
---
143
Edge level absolute
value (Monochrome
Cameras)
Set / Get
0 to 255
20
---
---
190
Judge-
ment
condi-
tions
Edge width upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9
999
---
Judgement
condition
191
Edge width lower limit
Set / Get
−
99,999.9999 to 99,999.9999
0
310
Logging
condi-
tions
Data logging switch for
entire unit
Set / Get
0: Data logging OFF
1: Data logging ON
1
---
---
311
Data logging switch for
judgement
Set / Get
0: Data logging OFF
1: Data logging ON
1
---
---
312
Data logging switch
for edge width
Set / Get
0: Data logging OFF
1: Data logging ON
1
---
---
700
Display
settings
Edge width display
Setting/
Acquisition
0: Display
1: Do not display
0
---
---
800
Wedge width display
pattern
Setting/
Acquisition
0: Absolute value
1: Relative value
2: Percentage
0
---
---
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......