![background image](http://html1.mh-extra.com/html/omron/fq2-s-ch-series/fq2-s-ch-series_user-manual_742878444.webp)
Menu Tables
442
FQ2-S/CH User’s Manual
*1
Refer to FQ2-S/CH Series User's Manual for Communications Settings (Cat. No. Z338).
Image ad
justmen
t (Po
si
tio
n
comp
ensat
ion it
ems)
Det
a
ils
Model parameters
(Shape Search and
Shape Search lll Posi-
tion Compensation
Items only)
• Shape Search Position Compensation Item and Search Position Compensa-
tion Item
Almost the same as for the Shape Search III, Shape Search II, and Search
inspection item.
However, the [Sub-pixel] and [Multi-point output] settings of the Search
inspection item do not exist.
• Edge Position Compensation, Two-edge Position Compensation, Two-edge Mid-
point Compensation, and Edge Rotation Position Compensation
The settings for the Edge Position Compensation item are almost the same as
those for the Edge Position inspection item.
Scene
---
Meas. Parameter
Scene
---
Output parameter
Scene
---
Scro
ll p
aramet
er
Source image
You can select the image to which to
apply the results of position compensa-
tion processing.
Camera
Prev. (Default)
Scene
Interpolation
You can select the precision of position
compensation.
Bilinear
None (Default)
Scene
for Posit
ion Compe
nsati
on (I
mage rot
ati
on,
P
aramet
er
)
Image rotation
Select to correct the position by rotating
the image around the center of the
screen.
−
180° to 180° (Default: 90°)
Scene
Pa
ramet
er
R
efe
rence posit
ion
Reference
position X
coordinate
Sets the X coordinate of the reference
position.
−
99999 to 99999
(Default: p. 127)
Scene
Reference
position Y
coordinate
Sets the Y coordinate of the reference
position.
−
99999 to 99999
(Default: p. 127)
Scene
Reference
angle
Sets the reference angle
θ
.
−
180 to 180 (Default: 90)
Scene
Measur
ement
posit
ion
Measure-
ment posi-
tion X
coordinate
Sets the X coordinate of the measure-
ment position.
−
99999 to 99999
(Default: p. 127)
Scene
Measure-
ment posi-
tion Y
coordinate
Sets the Y coordinate of the measure-
ment position.
−
99999 to 99999
(Default: p. 127)
Scene
Measure-
ment angle
Sets the measurement angle
θ
.
−
180 to 180 (Default: 0)
Scene
f
or Line
ar Corre
ct
ion
Ref. position
Sets the reference position.
---
Scene
Meas. position
Sets the measurement position.
---
Scene
Filter region
You can specify the range over which
position correction is performed.
---
Scene
Source image
You must set the image to which the filter
is to be applied.
Camera
Prev. (Default)
Scene
Interpolation
You can select the precision of position
compensation.
None
Bilinear (Default)
Scene
Menu command
Description
Setting range
Data
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......