Adjusting the Images That Were Taken
108
FQ2-S/CH User’s Manual
• Interpolation
You can select the precision of position compensation.
If you select [Bilinear], the precision of position compensation will increase.
[Image]
−
[Image adjustment]
−
[Search lll pos. comp.]
−
[Modify]
1
Press [Details]
−
[Scroll parameter]
−
[Interpolation]
2
Set the interpolation to [Bilinear] or [None].
• Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via Ethernet or used in
calculations.
Parameter
Setting
Description
Interpolation
Bilinear
Connects the points with a line and calculates an approximate
value,
Although, the processing time will be longer, a smooth image can
be acquired when you select [Bilinear],
None (Default)
Position compensation is performed at the pixel level.
Expression
text string
Data name
Description
Data range
JG
Judgement
This is the judgement result.
-2: No judgement (not measured)
0: Judgement is OK
-1: Judgement is NG
-10: Image inconsistency error
-15: Out of range error
DX
Scroll X
This is the amount of position
compensation for the X coordinate.
-99,999.9999 to 99,999.9999
DY
Scroll Y
This is the amount of position
compensation for the Y coordinate.
-99,999.9999 to 99,999.9999
DT
Scroll q
This is the amount of angular
compensation, q.
-180 to 180
X
Position X
This is the X coordinate of the position
where the model was found.
-99,999.9999 to 99,999.9999
Y
Position Y
This is the Y coordinate of the position
where the model was found.
-99,999.9999 to 99,999.9999
TH
Angle
This is the angle at which the model was
found.
-180 to 180
SX
Reference X
This is the X coordinate of the position
where the model was registered.
-99,999.9999 to 99,999.9999
SY
Reference Y
This is the Y coordinate of the position
where the model was registered.
-99,999.9999 to 99,999.9999
ST
Reference angle This is the angle when the model was
registered.
-180 to 180
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......