Inspecting with the Search Inspection Item
228
FQ2-S/CH User’s Manual
Changing Output Coordinate Positions
You can specify which part of the model to detect as coordinates during inspections. Normally, the center
position of the registered model is used as the detection point.
[Inspect]
−
[Inspection]
−
[Search]
−
[Modify]
−
[Settings] Tab Page
−
[Teach]
−
[ ]
−
[Detection point]
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via the Ethernet or
used in calculations.
1
Use one of the following methods to move the
cross cursor to the desired position.
The position of the cross cursor will be the coordi-
nate position that is output. This position is regis-
tered relative to the model region.
• Drag the cross cursor to move it.
• Press
[ ]
−
[Console] on the right of the display to
display the console. You can use the cross cursor
on the console to change the coordinate values one
pixel at a time.
The detection coordinates will automatically return to the center coordinates of the model if you change the model
region.
Expression
text string
Data name
Description
Data range
JG
Judgement
−
2: No judgment (not measured)
0: Judgment is OK
−
1: Judgment is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
This is the judgment result.
CR[0] to CR[31] Correlation
0 to 100
This is the correlation of the Nth model
that was found.
X[0] to X[31]
Position X
−
99,999.9999 to 99,999.9999
This is the X coordinate where the Nth
model was found.
Y[0] to Y[31]
Position Y
−
99,999.9999 to 99,999.9999
This is the Y coordinate where the Nth
model was found.
TH[0] to TH[31] Angle
−
180 to 180
This is the angle in which the Nth model
was found.
Drag the cross cursor.
Note
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......