External Reference Parameters
FQ2-S/CH User’s Manual
503
Appe
ndi
ce
s
9
128
Mea-
sure-
ment
condi-
tions
Hyphen height lower
threshold
Set / Get 0 to 100
70
---
---
129
Printing type
Set / Get 0: Solid character
1: Dot character
1
---
---
130
Rotation compensation
Set / Get 0: OFF
1: ON
0
---
---
131
Slant compensation
Set / Get 0: OFF
1: ON
1
---
---
132
Judge-
ment
condi-
tions
Similarity judgement upper
limit
Set / Get 0 to 100
100
---
Judgement
condition
133
Similarity judgement lower
limit
Set / Get 0 to 100
60
---
Judgement
condition
134
Stability judgement upper
limit
Set / Get 0 to 100
100
---
Judgement
condition
135
Stability judgement lower
limit
Set / Get 0 to 100
10
---
Judgement
condition
136
Output
parame-
ter
Line delimiter
Set / Get 0: None
1: Comma
2: Space
0
---
---
138
String output ON/OFF
Set / Get 0: OFF
1: ON
0
---
---
139
NG error code output
Set / Get 0: OFF
1: ON
1
---
---
141
*1
Error string
Set / Get 20 characters max.
NG
---
---
142
Partial output ON/OFF
Set / Get 0: No
1: Yes
0
---
---
143
Output end digit
Set / Get 1 to 128
128
---
---
144
Output beginning digit
Set / Get 1 to 128
1
---
---
146
Mea-
sure-
ment
condi-
tions
Reading speed
Set / Get 0: Fixed
1: Variable
1
---
---
150
*1
Format character string 0
Set / Get 32 characters max.
---
---
151
*1
Format character string 1
Set / Get 32 characters max.
---
---
152
*1
Format character string 2
Set / Get 32 characters max.
---
---
153
*1
Format character string 3
Set / Get 32 characters max.
---
---
154
*1
Teach mode
Set / Get 0: Simple teach
1: Correct string
1
---
---
155
*1
Correct string (L.1)
Set / Get 32 characters max.
---
---
156
*1
Correct string (L.2)
Set / Get 32 characters max.
---
---
157
*1
Correct string (L.3)
Set / Get 32 characters max.
---
---
158
*1
Correct string (L.4)
Set / Get 32 characters max.
---
---
160
Dictionary reference
Set / Get
−
1: None
0 to 31
−
1
---
---
170
Output
charac-
ter set
String output ON/OFF
(memory link)
Set / Get 0: OFF
1: ON
0
---
---
171
NG error code output
(memory link)
Set / Get 0: OFF
1: ON
1
---
---
172
Partial output ON/OFF
(memory link)
Set / Get 0: OFF
1: ON
0
---
---
Exter-
nal ref-
erence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......