Setting Up Ethernet
FQ2-S/CH User’s Manual
71
2
Install
ation an
d
C
onn
ecti
ons
Select the IP address to be used by PC Tool
The computer IP address, subnet address, and Default gateway that are used by the PC Tool are displayed.
If multiple IP addresses (network cards) exist in the computer, the IP address to be used for the PC Tool can be
selected.
(Setup Mode or Run Mode)
−
[TF settings]
−
[Ethernet]
−
[IP address]
1
A list of the computer IP addresses that can
be used by the PC Tool appears. Touch the
list to select
an IP address.
2
The Sensor List appears.
The connected sensor is temporarily discon-
nected.
To refresh the list, touch [Update list] of any
sensor.
3
Select the sensor that you want to connect
and touch [OK]. (The sensor is reconnect-
ed.)
• If you want to change the IP address, change the network settings of the computer and then select the IP address
using the above procedure.
• If the list does not appear, check if the LAN is correctly connected.