External Reference Parameters
FQ2-S/CH User’s Manual
479
Appe
ndi
ce
s
9
Erosion, Median, Extract Edges, Extract Horizontal Edges, Extract Vertical Edges, Enhance edges
Background Suppression
External
reference
number
Category
Data name
Set / Get
Data range
Default
Expression
text string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result
Judgement
Get only
−
2: No judgement (not measured),
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed error,
−
14: Figure not registered error,
−
15: Out of range error
−
2
JG
---
120
Mea-
sure-
ment
condi-
tions
Source image
Set / Get
0: Camera image,
1: Previous image
1
---
---
121
Setting method
Set / Get
0: Filtering OFF, 1: Filtering ON
1
---
---
External
reference
number
Category
Data name
Set / Get
Data range
Default
Expression
text string
Logged data/
Judgement
parameter
0
Measure-
ment
result
Judgement
Get only
−
2: No judgement
(not measured)
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
−
2
JG
---
120
Mea-
sure-
ment
condi-
tions
Source image
Set / Get 0: Camera image
1: Previous image
1
---
---
122
Image format
Set / Get
0: Binary image
1: Monochrome image
2: Color image
0
---
---
123
Color setting mode
Set / Get 0: RGB common, 1: RGB individ-
ual
0
---
---
124
Common color lower
limit
Set / Get 0 to 255
0
---
---
125
Common color upper
limit
Set / Get 0 to 255
255
---
---
126
R lower limit
Set / Get 0 to 255
0
---
---
127
R upper limit
Set / Get 0 to 255
255
---
---
128
G lower limit
Set / Get 0 to 255
0
---
---
129
G upper limit
Set / Get 0 to 255
255
---
---
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......