Menu Tables
FQ2-S/CH User’s Manual
463
Appe
ndi
ce
s
9
I/
O
sett
ing
O
u
tp
u
t da
ta
se
tt
ing Output character set Specifies the output settings for charac-
ters read by OCR, Bar code, 2D-code,
and 2D-code (DPM).
---
---
---*
1
String output on/
off
Selects whether the string that was read
is output.
ON
OFF (Default)
Scene
Partial output on/
off
Selects whether part of the string is to be
specified for output.
ON
OFF (Default)
Scene
Output string
setup
Species the part of the string that is out-
put.
1 to 1024
(Defaults: beginning: 1, end: 1024)
Scene
NG String out-
put on/off
Specifies whether NG strings are output.
ON
OFF (Default)
Scene
Output form
---
---
---
---*
1
Output form (No-
Protocol (TCP)
and No-Protocol
(UDP) only)
Selects the format of the data to be out-
put.
ASCII (Default)
Binary
Scene
---*
1
Whe
n o
ut
put
f
orma
t
is
A
S
CII
Digits of inte-
ger
Sets the digits of the integer part,
including the sign. However, + is not out-
put for positive numbers.
Example: Setting 4-digit data:
−
5963 is
output as -999.
1 to 10 (Default: 6)
Scene
Digits of dec-
imal
Sets the output digits for the decimal
part. If it is set to 0, the decimal part is
rounded off before the data is output.
0 to 4 (Default: 4)
Scene
Negative
Selects what to display as the sign when
the number is negative.
−
(Default)
8
Scene
0 suppress
Selects the method to adjust unused dig-
its on the left in output data.
Example:
The following examples are for when five
integer digits and three decimal digits are
set and the data is 100.000.
ON: 00100.000
OFF: _100.000 (The underscore indi-
cates a space.)
ON
OFF (Default)
Scene
Noprot
ocol da
ta out
put
Out
p
ut
fo
rm
W
h
en
Ou
tp
u
t
Fo
rm
a
t Is
A
S
CI
I
Field
separa-
tor
Selects the separator to use between
output data.
None (Default)
comma
tab, space
CR
LF
CR+LF
Scene
---*
1
Record
separa-
tor
Selects the separator to use between
sets of output data.
None (Default)
comma
tab space
CR
LF
CR+LF
Scene
Whe
n out
put
f
orma
t is
B
inary
Deci-
mal
output
form
Selects the numerical expression for
binary output.
Fixed-decimal-point data is multiplies by
1,000 and the result is output.
Floating-point decimal or fixed decimal
(Default)
Scene
Output form
(No-Protocol
(TCP) and
No-Protocol
(UDP) only)
Sets whether to output the data.
Floating-point decimal
Fixed decimal (Default)
Scene
---*
1
Menu command
Description
Setting range
Data
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......