Menu Tables
FQ2-S/CH User’s Manual
471
Appe
ndi
ce
s
9
Sensor
set
tings
Da
ta out
put
Li
nk da
ta
out
put
Area
set
tings
Out
put
A
rea t
yp
e
Sets the area to write output data from
measurements.
Output data 0 to 31
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (Default)
Work Area (WR)
Holding Bit Area (HR)
Auxiliary Bit Area (AR)
DM Area (DM)
EM Area (EM0)
EM Area (EM1)
:
EM Area (EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register (Default)
File Register
Link Register
System
---*
1
Address
Set the first address of the output area .
0 to 99999 (Default: 200)
System
Output hand-
shake
Sets whether to establish an interlock with
the PLC when data is output.
No (Default)
Yes
System
---*
1
Retry details
Enables or disables retrying communica-
tions.
ON (Default)
OFF
System
---*
1
Retry interval
Sets the interval for retrying communica-
tions. This setting is enabled only when
[Retry details] is set to [ON].
0 to 2,147,483,647 ms
(Default:10,000 ms)
System
---*
1
Max output data
Sets the upper limit of the number of out-
put data to use for PLC Link outputs.
Any output data that is beyond this value
is discarded.
32 to 1024 (Default: 256)
System
---*
1
Connection
mode
Sets the TCP connection mode.
TCP server (Default)
TCP client
System
---*
1
Data output
period
Set the period for outputting measurement
results.
This parameter is displayed and can be
set only when [Handshake setting] is set
to [No].
2 to 5,000 ms (Default: 40 ms)
System
---*
1
GATE signal ON
period
Set the time to turn ON the GATE signal.
This parameter is displayed and can be
set only when [Handshake setting] is set
to [No].
1 to 1,000 ms (Default: 20 ms)
System
---*
1
IP address
Sets the IP address to which to output.
* Setting is not possible if the connection
mode is set to a TCP server.
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 1 to 254
(Default:10.5.5.111)
System
---*
1
Output port No.
Sets the output port number.
* Setting is not possible if the connection
mode is set to a TCP server.
0 to 65535 (Default: 9600)
System
---*
1
Field
bus dat
a
ou
tpu
t set
tin
gs Communication
type
Specifies the type of communication used
for Fieldbus data output.
Invalid (Default)
EtherNet/IP
PROFINET
System
---*
1
Output hand-
shake
Sets whether to establish an interlock with
the PLC when data is output.
OFF: Outputs data regardless of the state
of the signal from the PLC.
Handshake: Outputs data after recognition
of DSA from the PLC.
No
Yes (Default)
System
---*
1
Output data size Sets the data size to output for EtherNet/
IP or PROFIBUS output. If the data size
that is set is exceeded, data will be output
in more than one transfer.
32 bytes (Default)
64 bytes
128 bytes
256 bytes
System
---*
1
Refreshing task
period
Set the communications cycle for cyclic
tag data link communications for the Sen-
sor.
1 to 10,000 ms
(Default:10 ms)
System
---*
1
Menu command
Description
Setting range
Data
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......