![background image](http://html1.mh-extra.com/html/omron/fq2-s-ch-series/fq2-s-ch-series_user-manual_742878566.webp)
Specifications and Dimensions
564
FQ2-S/CH User’s Manual
Sensor Data Units
Specifications
Table 1
*1:
Do not allow the load current to exceed 50 mA. The output circuit may be damaged if the load current exceeds 50 mA.
Item
Sensor Data Unit
s
FQ-SDU1
Parallel Interface Sensor Data Unit (SDU10: NPN, SDU15: PNP)
FQ-SDU2
RS-232C Interface Sensor Data Unit (SDU20: NPN, SDU25: PNP)
I/O
specifi-
cations
Parallel I/
O
SDU1
11 inputs (TRIG, RESET, IN0 to IN7, and DSA)
24 outputs (GATE, D0 to D15, ACK, RUN, BUSY, OR, ERROR, STGOUT, and SHTOUT)
SDU2
8 inputs (IN0 to IN5, TRIG, and RESET)
7 outputs (ACK, RUN, BUSY, OR, ERROR, STGOUT, SHTOUT)
RS-232C
1 channel, 115,200 bps max.
*FQ-SDU2
only.
Sensor interface
FQ2-S3, FQ2-S4, FQ2-CH connected with FQ-WU
): OMRON interface
*Number of connected Sensors: 1
Input specifications
Refer to Table 2.
Output specifications
Rat-
ings
Power supply voltage
21.6 to 26.4 VDC (including ripple)
Insulation resistance
Between all DC external terminals and case: 0.5 M
Ω
min. (at 250 VDC)
Current consumption
2.5 A max. (FQ2-CH, FQ2-S
-
+ FQ-SDU
)
0.4 A max. (FQ2-S3
-
+ FQ-SDU
,
FQ2-S4
-
+ FQ-SDU
)
0.1 A max. (for FQ-SDU
)
Envi-
ron-
mental
immu-
nity
Ambient temperature
range
Operating: 0 to 50
°
C, Storage:
−
20 to 65
°
C (with no icing or condensation)
Ambient humidity
range
Operating and storage: 35% to 85% (with no condensation)
Ambient atmosphere
No corrosive gas
Vibration resistance
(destruction)
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions, 8 min each, 10 times
Shock resistance
(destruction)
150 m/s
2
3 times each in 6 directions (up, down, right, left, forward, and backward)
Degree of protection
IEC 60529 IP20
Materials
Case: PC + ABS, PC
Size
62
×
90
×
65 (W
×
H
×
D) (Excluding connectors, DIN Track, and protrusions.)
Weight
Approx. 150 g
Accessories
Instruction Manual
Item
NPN
PNP
Input specifi-
cations
ON: Shorted to 0 V, or 1.5 V max.
OFF: Open (leakage current: 0.1 mA max.)
ON: Shorted to power supply voltage, or power supply volt-
age
−
1.5 V max.
OFF: Open (leakage current: 0.1 mA max.)
Output speci-
fications
*1
NPN open collector
30 VDC, 50 mA max., residual voltage: 1.2 V max.
PNP open collector
30 VDC, 50 mA max., residual voltage: 1.2 V max.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......