Calculations and Judgments Using Inspection Item Data
336
FQ2-S/CH User’s Manual
Shape Search II
Shape Search lll
(FQ2-S1/S2/S3/S4 only)
Judgement
JG
−
2: No judgement (not measured)
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
−
2
Correlation
CR
0 to 100
0
Position X
X
−
99999.9999 to 99999.9999
0
Position Y
Y
−
99999.9999 to 99999.9999
0
Angle
TH
−
180 to 180
0
Reference X
SX
−
99999.9999 to 99999.9999
0
Reference Y
SY
−
99999.9999 to 99999.9999
0
Reference angle
ST
−
180 to 180
0
Detection X
RX
−
99999.9999 to 99999.9999
0
Detection Y
RY
−
99999.9999 to 99999.9999
0
Count
C
0 to 32
0
Sensitive Search
(FQ2-S1/S2/S3/S4 only)
Judgement
JG
−
2: No judgement (not measured)
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
−
2
Correlation
CR
0 to 100
0
Density
DV
Color image: 0 to 221
0
Monochrome image: 0 to 127
0
Position X
X
−
99999.9999 to 99999.9999
0
Position Y
Y
−
99999.9999 to 99999.9999
0
Angle
TH
−
180 to 180
0
Detection X
RX
−
99999.9999 to 99999.9999
0
Detection Y
RY
−
99999.9999 to 99999.9999
0
Ref. position X
(reference position X)
SX
−
99999.9999 to 99999.9999
0
Ref. position Y
(reference position Y)
SY
−
99999.9999 to 99999.9999
0
Reference angle
ST
−
180 to 180
0
NG sub-region
CT
0 to 100
0
Sub-region number
AN
1 to 99
0
Sub-region number(X)
ANX
0 to 9
0
Sub-region number(Y)
ANY
0 to 9
0
Sub-region pos.X
(sub-region position X)
DX
−
99999.9999 to 99999.9999
0
Sub-region pos.Y
(sub-region position Y)
DY
−
99999.9999 to 99999.9999
0
Correlation (sub-region)
CRN[0] to
CRN[80]
0 to 100
0
Deviation (sub-region)
DVN[0] to
DVN[80]
Color image: 0 to 221
0
Monochrome image: 0 to 127
0
Inspection item
Data name
Expression
text string
Data range
Default
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...