External Reference Parameters
FQ2-S/CH User’s Manual
521
Appe
ndi
ce
s
9
142
Verifica-
tion con-
dition
Verification master data Set / Get
−
1: OFF
0: All master data
1: Master data 0 verification
2: Master data 1 verification
:
32: Master data 31 verification
−
1
---
---
143
Partial verification ON/
OFF
Set / Get 0: No 1: Yes
0
---
---
144
Verification end digit
Set / Get 1 to 1024
1024
---
---
145
Verification beginning
digit
Set / Get 1 to 1024
1
---
---
150
Selected master num-
ber
Set / Get 0 to 31
0
---
---
152
Auto master data num-
ber
Set / Get 0 to 31: Master data number
−
1: OFF
−
1
---
---
161
Judge-
ment
condi-
tion
threshold
Upper limit for cell rec-
ognition rate threshold
Set / Get 0 to 100
100
---
Judgement
condition
162
Lower limit for cell rec-
ognition rate threshold
Set / Get 0 to 100
0
---
Judgement
condition
163
Contrast threshold
upper limit
Set / Get 0 to 100
100
---
Judgement
condition
164
Contrast threshold
lower limit
Set / Get 0 to 100
0
---
Judgement
condition
165
Focus threshold upper
limit
Set / Get 0 to 100
100
---
Judgement
condition
166
Focus threshold lower
limit
Set / Get 0 to 100
0
---
Judgement
condition
167
Threshold upper limit
for print quality DPM
Set / Get 0 to 4
4
---
Judgement
condition
168
Threshold lower limit
for print quality DPM
Set / Get 0 to 4
0
---
Judgement
condition
170
Output
parame-
ter
String output ON/OFF
(memory link)
Set / Get 0: OFF
1: ON
0
---
---
171
NG error code output
(memory link)
Set / Get 0: OFF
1: ON
1
---
---
172
Partial output ON/OFF
(memory link)
Set / Get 0: OFF
1: ON
0
---
---
173
Output end digit (mem-
ory link)
Set / Get 1 to 1024
1024
---
---
174
Output beginning digit
(memory link)
Set / Get 1 to 1024
1
---
---
186
Mea-
sure-
ment
condition
DPM print quality
Set / Get 0: OFF
1: ON
0
---
---
190
Grid correction (Data-
Matrix)
Set / Get 0: OFF
1: ON
0
---
---
191
Grid correction (QR
codes)
Set / Get 0: OFF
1: ON
0
---
---
202+3
×
N
(N=0 to
31)
*1
Verifica-
tion con-
dition
Master data N
Set / Get 32 characters max.
---
---
---
300+N
(N=0 to
31)
Reference unit number
N
Set / Get 0 to 31
0
---
---
External
refer-
ence
number
Category Data name
Set / Get Data range
Default
Expres-
sion text
string
Logged
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......