Logging Measurement Data and Image Data
FQ2-S/CH User’s Manual
397
7
Conven
ien
t Fu
ncti
ons
Storage Locations and File Names for Logged File Data
*1:
A five-digit number is assigned as a name to the image data storage folder in the order of folder creation as shown below.
Up to 100 images are stored in each folder.
00000
00001
:
:
*2:
Files are stored in the following folder when the PC Tool is used.
\My Documents\OMRON FQ\SDCard
*3:
"n" is a serial number that is added when images are logged at the same time.
*4:
You can change the "img" at the beginning of the file name.
*5:
You can add a character string to the beginning of the file name.
*6:
Measurement ID is a value equal to the measurement count minus 1.
When launching the FQ2, the count starts from zero.
• Setting the File Name for Logged Data
You can set a character string to add to the beginning of the file name for logged data.
Image data: You can change the “img_” at the beginning of the file name for logged data to another text string.
Measurement data: You can add a character string to the beginning of the file name for logged data.
(Setup Mode or Run Mode)
−
[TF settings]
−
[File format]
1
Select the item for which to add to or change the file name and then press [Logging image file]
or [Logging data file].
2
Press [File name prefix].
3
Enter the file name (up to 15 alphanumeric characters) and press [OK].
4
Press [OK].
Data
Storage location
File name
TouchFinder
TouchFinder for PC
Image logging
(image data)
\sensor_name\
LOGIMAGE\number
*1
\My Docu-
ments\OMRON
FQ\SDCard/Sensor
name\LOGIMAGE\
img_Scnxxx_YYYY_MM_DD-HH_MM_SS(n)_
Mea-
surementID
_
OverallJudgementResult
.IFZ
*3,*4,*5
Example: The following name would be used for mea-
surements performed at 10:10:21 pm on May 10, 2012
when Scene1 is set, and it’s measurement
result is OK. Then Image logging (image data) is as
below.
img_Scn001_2012_05_10-
22_10_21(0)_0000_OK.IFZ.IFZ
Data logging
(measurement data)
\sensor_name\LOG-
DATA
\My Docu-
ments\OMRON
FQ\SDCard\Sensor
name\LOGDATA
YYYY_MM_DD-HH_MM_SS.CSV
*6
Example: The following name would be used for mea-
surements performed at 10:10:21 pm on May 10
2012: 2012_05_10-22_10_21.CSV
• TouchFinder file save capacity is limited by capacity of SD card.
• TouchFinder for PC's file save capacity is limited by capacity of your PC's hard disk.
Note
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......