Specifications and Dimensions
FQ2-S/CH User’s Manual
555
Appe
ndi
ce
s
9
I/O specifica-
tions
Input signals
7 signals
• Single measurement input (TRIG)
• Control command input (IN0 to IN5)
Output signals
3 signals
• Control output (BUSY)
• Overall judgement output (OR)
• Error output (ERROR)
Note: The assignments of the three output signals (OUT0 to OUT2) can
also be changed
to the following.
・
READY
・
RUN
・
STG (Strobe trigger)
・
OR (Item0 judgment) to OR31 (Item31 judgment)
・
Exp.0 judgment to Exp.31 judgment
Ethernet specifications
100Base-TX/10Base-T
Communications
Ethernet TCP no-protocol,
Ethernet UDP no-protocol,
Ethernet FINS/TCP no-protocol,
EtherNet/IP,
PLC Link, or
PROFINET
I/O expansion
Possible by connecting FQ-SDU1
Sensor Data Unit
.
.
11 inputs and 32 outputs
RS-232C
Possible by connecting FQ-SDU2
Sensor Data Unit
.
.
Input specifications
Refer to Table 2.
Output specifications
Connection method
Special connector cables
Power supply and I/O: 1 cable (FQ-WD
)
Touch Finder and computer: 1 cable (FQ-WN
)
Indications
BUSY indicator (BUSY, green), Judgement result indicator (OR, orange),
error indicator (ERROR, red), Ethernet communications indicator (ETN,
orange)
Note: The assignment of the BUSY indicator can be changed to a RUN indi-
cator (display color: green).
Ratings
Power supply voltage
21.6 to 26.4 VDC (including ripple)
Insulation resistance
Between all lead wires and case: 0.5 M
Ω
(at 250 V)
Current consumption
2.4 A max.
Environmental
immunity
Ambient temperature range
Operating: 0 to 50
°
C
Storage:
−
25 to 65
°
C
(with no icing or condensation)
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Ambient atmosphere
No corrosive gas
Vibration resistance (destruction)
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions
8 min each, 10 times
Shock resistance (destruction)
150 m/s
2
3 times each in 6 direction (up, down, right, left, forward, and
backward)
Degree of protection
IEC 60529 IP67 (Except when Polarizing Filter Attachment is mounted or
connector cap is removed.)
Materials
Sensor: PBT, PC, SUS
Mounting Bracket: PBT
Polarizing Filter Attachment: PBT, PC
Ethernet connector: Oil-resistance vinyl compound
I/O connector: Lead-free heat-resistant PVC
Weight
Depends on field of view and installation distance. Refer to Table 1.
Item
Inspection and ID models
Model
NPN
FQ2-CH10
-M
PNP
FQ2-CH15
--M
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......