![background image](http://html1.mh-extra.com/html/omron/fq2-s-ch-series/fq2-s-ch-series_user-manual_742878535.webp)
External Reference Parameters
FQ2-S/CH User’s Manual
533
Appe
ndi
ce
s
9
150
Mea-
sure-
ment
condi-
tions
Edge level
(measurement)
Set / Get 0 to 1024
30
---
---
152
Extraction condition, X
upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
153
Extraction condition, X
lower limit
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
154
Extraction condition, Y
upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
155
Extraction condition, Y
lower limit
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
160
Image type
Set / Get
0: Measurement image
1: Measurement image + Model
image
2: Edge image
3: Edge image + Model image
1
---
161
Detection count
Set / Get 1 to 32
32
---
---
172
Edge level auto
(measurement)
Set / Get 0: OFF
1: ON
1
---
---
174
Mask size
Set / Get
0: 3 x 3
1: 5 x 5
2: 7 x 7
0
---
---
178
Edge level auto
(model)
Set / Get 0: OFF
1: ON
1
---
---
180
Acceptable distortion
level
Set / Get
0: Low
1: Middle
2: High
2
---
---
181
Noise Removal Level
Set / Get 0 to 100
0
---
---
188
Model mode
Set / Get 0: Stable
1: Fast
0
---
---
229
Overlay judgement
Set / Get 0: No
1: Yes
0
---
---
230
Overlay rejection
Set / Get 0 to 100
100
---
---
300
Logging
condi-
tions
Number of data log
records upper limit
Set / Get 1 to 32
32
---
---
310
Data logging switch for
entire unit
Set / Get 0: Data logging OFF
1: Data logging ON
1
---
---
311
Data logging switch for
judgement
Set / Get 0: Data logging OFF
1: Data logging ON
1
---
---
312
Data logging switch for
correlation
Set / Get 0: Data logging OFF
1: Data logging ON
1
---
---
313
Data logging switch for
position X
Set / Get 0: Data logging OFF
1: Data logging ON
1
---
---
314
Data logging switch for
position Y
Set / Get 0: Data logging OFF
1: Data logging ON
1
---
---
315
Data logging switch for
measurement angle
Set / Get 0: Data logging OFF
1: Data logging ON
1
---
---
321
Data logging switch for
detection count
Set / Get 0: Data logging OFF
1: Data logging ON
1
---
---
External
refer-
ence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......