![background image](http://html1.mh-extra.com/html/omron/fq2-s-ch-series/fq2-s-ch-series_user-manual_742878126.webp)
Adjusting the Images That Were Taken
124
FQ2-S/CH User’s Manual
• Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via Ethernet or used in
calculations.
Expression
text string
Data name
Description
Data range
JG
Judgement
This is the judgment result.
-2: No judgement
(not measured)
0: Judgement is OK
-1: Judgement is NG
-15: Out of range error
DT
Scroll q
This is the amount of position
compensation.
-180 to 180
X0
Edge 0 position X
This is the X coordinate of the
measured edge 0 position.
-99,999.9999 to 99,999.9999
Y0
Edge 0 position Y
This is the Y coordinate of the
measured edge 0 position.
-99,999.9999 to 99,999.9999
X1
Edge 1 position X
This is the X coordinate of the
measured edge 1 position.
-99,999.9999 to 99,999.9999
Y1
Edge 1 position Y
This is the Y coordinate of the
measured edge 1 position.
-99,999.9999 to 99,999.9999
TH
Angle (edge angle)
This is the measured angle.
-180 to 180
SX0
Edg0 ref. pos.
(edge 0 reference position X)
This is the X coordinate of the
edge 0 position when it was regis-
tered.
-99,999.9999 to 99,999.9999
SY0
Edg0 ref. pos. Y
(edge 0 reference position Y)
This is the Y coordinate of the
edge 0 position when it was reg-
istered.
-99,999.9999 to 99,999.9999
SX1
Edg1 ref. pos. X
(edge 1 reference position X)
This is the X coordinate of the
edge 1 position when it was regis-
tered.
-99,999.9999 to 99,999.9999
SY1
Edg1 ref. pos. Y
(edge 1 reference position Y)
This is the Y coordinate of the
edge 1 position when it was regis-
tered.
-99,999.9999 to 99,999.9999
STH
Reference angle
This is the angle when the edge
was registered.
-180 to 180
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......