Adjusting the Images That Were Taken
96
FQ2-S/CH User’s Manual
Setting the Filter Type (for Color Gray Filter Only)
You can specify the ranges of colors to which the Color Gray Filter item is applied.
[Image]
−
[Image adjustment]
−
[Add filter]
−
[Color Gray Filter]
1
Press [ ]
−
[Filter type] on the right of the display.
2
Set the filter type to either [RGB] or [HSV].
3
Press [ ]
−
[Filter settings] on the right of the display.
4
Make the detailed filter settings.
• RGB
Select the type of color filter to use.
If you select [Custom filter], set the gains for red, green,
and blue.
• HSV
Set the following ranges: [Std. Hue], [Hue range], and
[Chroma].
Parameter
Description
RGB
(Default)
The red, green, and blue extraction
ranges are specified.
HSV
The extracted color ranges are specified
with the hue and chroma (saturation).