![background image](http://html1.mh-extra.com/html/omron/fq2-s-ch-series/fq2-s-ch-series_user-manual_742878499.webp)
External Reference Parameters
FQ2-S/CH User’s Manual
497
Appe
ndi
ce
s
9
187
Judge-
ment
condi-
tions
Edge position Y upper
limit 1
Set / Get
−
|99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
188
Edge position Y lower
limit 1
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
190
Edge midpoint position
X upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
191
Edge midpoint position
X lower limit
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
192
Edge midpoint position
Y upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
193
Edge midpoint position
Y lower limit
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
194
Position compensation
X upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
195
Position compensation
X lower limit
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
196
Position compensation
Y upper limit
Set / Get
−
99,999.9999 to 99,999.9999
99,999.9999
---
Judgement
condition
197
Position compensation
Y lower limit
Set / Get
−
99,999.9999 to 99,999.9999
−
99,999.9999
---
Judgement
condition
310
Logging
condi-
tions
Data logging switch for
entire unit
Set / Get 0: Data logging OFF,
1: Data logging ON
0
---
---
311
Data logging switch for
judgement
Set / Get 0: Data logging OFF,
1: Data logging ON
0
---
---
312
Data logging switch for
scroll X
Set / Get 0: Data logging OFF,
1: Data logging ON
0
---
---
313
Data logging switch for
scroll Y
Set / Get 0: Data logging OFF,
1: Data logging ON
0
---
---
314
Data logging switch
for detected edge posi-
tion X0
Set / Get 0: Data logging OFF,
1: Data logging ON
0
---
---
315
Data logging switch
for detected edge posi-
tion Y0
Set / Get 0: Data logging OFF,
1: Data logging ON
0
---
---
316
Data logging switch
for detected edge posi-
tion X1
Set / Get 0: Data logging OFF,
1: Data logging ON
0
---
---
317
Data logging switch
for detected edge posi-
tion Y1
Set / Get 0: Data logging OFF,
1: Data logging ON
0
---
---
318
Logging
condi-
tions
Data logging switch
for detected edge mid-
point position X
Set / Get 0: Data logging OFF,
1: Data logging ON
0
---
---
319
Data logging switch
for detected edge mid-
point position Y
Set / Get 0: Data logging OFF,
1: Data logging ON
0
---
---
Exter-
nal ref-
erence
number
Category Data name
Set / Get Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......