Inspecting with the Labeling Inspection Item
318
FQ2-S/CH User’s Manual
Changing the Label Extraction Conditions
Set the label extraction conditions. You can select to extract only labels that satisfy all four of the following:
Number of labels, specified area, gravity X, and gravity Y conditions.
[Inspect]
−
[Inspection]
−
[Labeling]
−
[Modify]
−
[Settings] Details
−
[Details] Tab Page
−
[Meas. Parameter]
−
[Extraction condition]
1
Press and set each of the parameters
for the extraction conditions.
Parameter
Setting
Description
Number of labels
Range: 1 to 100
Default: 100
Set the maximum number of labels to
detect.
Area
Range: 0 to 999,999,999.9999
Defaults: Upper limit: 999,999,999.9999
Lower limit: 0
Specify the area range to judge as a
label.
Gravity X
Range:
−
99,999,999.9999 to 999,999,999.999
Defaults:
Upper limit: 999,999,999.999,
Lower limit:
−
999,999,999.9999
Specify the gravity X position to judge as
a label.
Gravity Y
Range:
−
999,999,999.9999 to 999,999,999.999
Defaults:
Upper limit: 999,999,999.999,
Lower limit:
−
999,999,999.9999
Specify the gravity Y position to judge as
a label.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......