HYDRAULIC ATTACHMENT SYSTEM
Hydraulic Pump Assembly
2007 Carryall 295/295 SE & XRT 1550/1550 SE Gasoline, Diesel and IntelliTach M & S Manual
Page 16-47
16
8. Connect the battery cables, positive (+) cable first, and tighten the terminals to 144 in-lb (16 N·m). Coat
terminals with Battery Terminal Protector Spray (CCI P/N 1014305).
9. Refill and prime system.
See Priming the Pump, Section 16, Page 16-49.
RESERVOIR
Reservoir Removal
1. Remove pump assembly.
See Pump Assembly Removal on page 16-44.
2. Lift pump assembly and place it, motor end up, into drain pan. Remove filler cap to drain most of the fluid
into pan.
3. Clean and inspect filler cap. Replace cap if damaged or unable to clean.
4. Loosen band clamp and remove reservoir
(Figure 16-91, Page 16-47)
.
Reservoir Installation
1. Drain remaining fluid and wipe or flush reservoir clean.
2. Clean or replace suction tube filter
(Figure 16-92, Page 16-47)
.
3. Wipe/rinse the pump clean.
4. Clean and inspect reservoir o-ring. Replace if necessary.
5. Lubricate o-ring with new fluid and install reservoir being careful not to pinch or deform the o-ring. Tighten
clamp to 57 in-lb (6.3 N·m).
6. Install pump assembly.
See Pump Assembly Installation on page 16-46.
Figure 16-91 Loosen Band Clamp
Figure 16-92 Suction Tube Filter
Summary of Contents for IntelliTach XRT 1550
Page 2: ......
Page 22: ...1...
Page 54: ...4...
Page 60: ...5...
Page 90: ...6...
Page 114: ...8...
Page 118: ...9...
Page 196: ...11A...
Page 290: ...11C...
Page 468: ...13C...
Page 490: ...14...
Page 498: ...15...
Page 548: ...16...
Page 560: ...Club Car R NOTES...
Page 561: ...Club Car R NOTES...
Page 562: ...Club Car R NOTES...
Page 563: ......