11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 37
(4) Mounting hole machining dimensions
The following shows mounting hole dimensions for mounting the heat generation area of the power
regeneration converter outside a cabinet as measures against heat generation when the converter is
mounted in an enclosed type cabinet.
[Unit: mm]
(AA)
(BA)
b
a
(2-
φ
D hole)
(Mounting hole)
Power regeneration
converter
a b D AA
BA
FR-RC-15K 260
412
10
200
432
FR-RC-30K 330
562
10
270
582
FR-RC-55K 470
642
12
410
670
FR-RC-H15K
330 562 10 270 582
FR-RC-H30K
FR-RC-H55K 470
642
12
410
670
11.5 FR-CV-(H) power regeneration common converter
POINT
For details of the power regeneration common converter FR-CV-(H), refer to the
FR-CV Installation Guide (IB(NA)0600075).
Do not supply power to the main circuit power supply terminals (L1, L2, and L3)
of the servo amplifier. Doing so will fail the servo amplifier and FR-CV-(H).
Connect the DC power supply between the FR-CV-(H) and servo amplifier with
correct polarity. Connection with incorrect polarity will fail the FR-CV-(H) and
servo amplifier.
Two or more FR-CV-(H)s cannot be installed to improve regeneration capability.
Two or more FR-CV-(H)s cannot be connected to the same DC power supply
line.
When using FR-CV-(H), set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced stop
1).
When using the FR-CV-(H) power regeneration common converter, set [Pr. PA02] to "_ _ 0 1" and set [Pr.
PC20] to "_ _ _ 1".
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...