5. PARAMETERS
5 - 32
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT EIP
PB18
LPF
Low-pass
filter setting
Set the low-pass filter.
The following shows a relation of a required parameter to this parameter.
Setting range: 100 to 18000
3141
[rad/s]
[Pr. PB23]
[Pr. PB18]
_ _ 0 _ (Initial value)
Automatic setting
_ _ 1 _
Setting value
enabled
_ _ 2 _
Setting value
disabled
PB19
VRF11
Vibration
suppression
control 1 -
Vibration
frequency
Set the vibration frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is used as
it is. Refer to section 7.1.5 for details.
Setting range: 0.1 to 300.0
100.0
[Hz]
PB20
VRF12
Vibration
suppression
control 1 -
Resonance
frequency
Set the resonance frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is used as
it is. Refer to section 7.1.5 for details.
Setting range: 0.1 to 300.0
100.0
[Hz]
PB21
VRF13
Vibration
suppression
control 1 -
Vibration
frequency
damping
Set a damping of the vibration frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is used as
it is. Refer to section 7.1.5 for details.
Setting range: 0.00 to 0.30
0.00
PB22
VRF14
Vibration
suppression
control 1 -
Resonance
frequency
damping
Set a damping of the resonance frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is used as
it is. Refer to section 7.1.5 for details.
Setting range: 0.00 to 0.30
0.00
PB23
VFBF
Low-pass
filter selection
_ _ _ x Shaft resonance suppression filter selection
Select the shaft resonance suppression filter.
0: Automatic setting
1: Manual setting
2: Disabled
When you select "Enabled (_ _ _ 1)" of "Machine resonance suppression filter 4
selection" in [Pr. PB49], the shaft resonance suppression filter is not available.
0h
_ _ x _ Low-pass filter selection
Select the low-pass filter.
0: Automatic setting
1: Manual setting
2: Disabled
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...