4. STARTUP
4 - 16
(2) Operation procedure
1) Turn off the power.
2) Turn "ON (up)" SW1-1.
1
ON
2
Set SW1-1 to "ON (up)".
1
ON
2
Turning "ON (up)" SW1-1 during power-on will not start the test operation mode.
3) Turn on the servo amplifier.
When initialization is completed, the decimal point on the first digit will flicker.
After 1.6 s
After 0.2 s
Flickering
When an alarm or warning also occurs during the test operation, the decimal point on the first
digit will flicker as follows.
After 0.8 s
After 0.8 s
After 0.2 s
Flickering
Flickering
4) Start operation with the personal computer.