5. PARAMETERS
5 - 81
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT EIP
PT72
ECMXL
Synchronous
encoder
electronic
gear -
Numerator
(lower four
digits)
Set an electronic gear numerator for converting a synchronous encoder command
into a command unit. Upper and lower are a set.
Set the electronic gear in hexadecimal.
Setting value of this parameter:
[Pr. PT72]
[Pr. PT73]
Upper four
digits
Lower four
digits
Set a value within the following range. When a value outside the range is set,
synchronous control error will occur and synchronous control will not start even
though Synchronous control command (Control DI7 bit 12) is input.
Setting "0" will apply "1".
1
16000
Synchronous encoder electronic gear - Numerator
Synchronous encoder electronic gear - Denominator
<
< 6000
To enable the parameter value, cycle the power or turn on Analysis command
(Control DI 7 bit 14).
This parameter corresponds to "External encoder gear numerator (Class ID: 64h, Ins
ID: 2DF0h, Attr ID: 1)". When this parameter is mapped for the I/O communication,
the value written with MR Configurator2 is overwritten with the controller. Thus, do
not write a value with MR Configurator2.
Setting range: 0000h 0000h to FFFFh FFFFh
0000h
PT73
ECMXH
Synchronous
encoder
electronic
gear -
Numerator
(upper four
digits)
Set an electronic gear numerator for converting a synchronous encoder command
into a command unit. Upper and lower are a set.
Refer to [Pr. PT72] for details.
0000h
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...