2. INSTALLATION
2 - 6
2.6 Restrictions when using the servo amplifiers at altitude exceeding 1000 m and up to 2000 m above sea
level
(1) Effective load ratio and regenerative load ratio
Heat dissipation effects decrease in proportion to decreasing air density, and hence use the servo
amplifiers with the effective load ratio and the regenerative load ratio within the following range.
0
2000
1000
Altitude
95
100
0
Regenerat
ive load rat
io
E
ffe
ct
ive load rat
io
[%]
[m]
When closely mounting the servo amplifiers, operate them at the ambient temperatures of 0
˚
C to 45
˚
C
or at 75% or smaller effective load ratio. (Refer to section 2.1.)
(2) Input voltage
Generally, withstand voltage decreases as increasing altitude; however, there is no restriction on the
withstand voltage. Use in the same manner as in 1000 m or less. (Refer to section 1.3.)
(3) Parts having service lives
(a) Smoothing capacitor
The capacitor will reach the end of its life in 10 years of continuous operation in air-conditioned
environment (ambient temperature of 30
˚
C or less).
(b) Relays
There is no restriction. Use in the same manner as in 1000 m or less. (Refer to section 2.5.)
(c) Servo amplifier cooling fan
There is no restriction. Use in the same manner as in 1000 m or less. (Refer to section 2.5.)
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...