App. 4.3 Mounting/dismounting
Installation direction and clearances
CAUTION
The devices must be installed in the specified direction. Not doing so may cause
a malfunction.
Mount the servo amplifier on a cabinet which meets IP54 in the correct vertical
direction to maintain pollution degree 2.
The regenerative resistor supplied with 11 kW to 22 kW servo amplifiers does not
have a protective cover. Touching the resistor (including wiring/screw hole area)
may cause a burn injury and electric shock. Even if the power was shut-off, be
careful until the bus voltage discharged and the temperature decreased because
of the following reasons.
It may cause a burn injury due to very high temperature without cooling.
It may cause an electric shock due to charged capacitor of the servo amplifier.
10 mm or
more
80 mm or longer
for wiring
10 mm or
more
(Note 2)
Top
Bottom
40 mm or
more
(Note 1)
40 mm or
more
Cabinet
Servo amplifier
Ser
vo amplifier
Cabinet
Note 1. For 11 kW to 22 kW servo amplifiers, the clearance between the bottom and
ground will be 120 mm or more.
2. For MR-J4-500TM, the clearance on the left side will be 25 mm or more.