5. PARAMETERS
5 - 64
5.2.7 Linear servo motor/DD motor setting parameters ([Pr. PL_ _ ])
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT EIP
PL01
**LIT1
Linear servo
motor/DD
motor
function
selection 1
_ _ _ x Linear servo motor/DD motor magnetic pole detection selection
The setting value "0" will be enabled only with absolute position linear encoders.
0: Magnetic pole detection disabled
1: Magnetic pole detection at first servo-on
5: Magnetic pole detection at every servo-on
1h
_ _ x _ For manufacturer setting
0h
_ x _ _ Stop interval selection at the home position return
Set a stop interval for the dog type home position return.
The digit is enabled only for linear servo motors.
0: 2
13
(= 8192) pulses
1: 2
17
(= 131072) pulses
2: 2
18
(= 262144) pulses
3: 2
20
(= 1048576) pulses
4: 2
22
(= 4194304) pulses
5: 2
24
(= 16777216) pulses
6: 2
26
(= 67108864) pulses
3h
x _ _ _ For manufacturer setting
0h
PL02
**LIM
Linear
encoder
resolution -
Numerator
Set a linear encoder resolution with the settings of [Pr. PL02] and [Pr. PL03].
Set a numerator to [Pr. PL02].
This is enabled only for linear servo motors.
Setting range: 1 to 65535
1000
[µm]
PL03
**LID
Linear
encoder
resolution -
Denominator
Set a linear encoder resolution with the settings of [Pr. PL02] and [Pr. PL03].
Set a denominator to [Pr. PL03].
This is enabled only for linear servo motors.
Setting range: 1 to 65535
1000
[µm]
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...