3. SIGNALS AND WIRING
3 - 22
You can also use a ferrule to connect with the connectors. When using a ferrule, select a ferrule and
crimping tool listed in the table below.
Servo amplifier
Wire size
Ferrule model (Phoenix Contact)
Crimping tool
(Phoenix Contact)
For one
For two
MR-J4-10TM to
MR-J4-100TM
AWG 16
AI1.5-10BK
AI-TWIN2×1.5-10BK
CRIMPFOX-ZA3
AWG 14
AI2.5-10BU
MR-J4-200TM to
MR-J4-350TM
AWG 16
AI1.5-10BK
AI-TWIN2×1.5-10BK
AWG 14
AI2.5-10BU
AI-TWIN2×2.5-10BU
AWG 12
AI4-10GY
MR-J4-60TM4 to
MR-J4-350TM4
AWG 16
AI1.5-10BK
AI-TWIN2×1.5-10BK
AWG 14
AI2.5-10BU
MR-J4-10TM1 to
MR-J4-40TM1
AWG 16
AI1.5-10BK
AI-TWIN2×1.5-10BK
AWG 14
AI2.5-10BU
(b) Inserting wire
Insert the open tool as follows and push down it to open the spring. While the open tool is pushed
down, insert the stripped wire into the wire insertion hole. Check the insertion depth so that the cable
insulator does not get caught by the spring.
Release the open tool to fix the wire. Pull the wire lightly to confirm that the wire is surely connected.
The following shows a connection example of the CNP3 connector for MR-J4-200TM and MR-J4-
350TM.
1) Push down the open tool.
3) Release the open tool to fix the wire.
2) Insert the wire.