2. INSTALLATION
2 - 2
2.1 Installation direction and clearances
CAUTION
The equipment must be installed in the specified direction. Otherwise, it may
cause a malfunction.
Leave specified clearances between the servo amplifier and the cabinet walls or
other equipment. Otherwise, it may cause a malfunction.
(1) Installation clearances of the servo amplifier
(a) Installation of one servo amplifier
Cabinet
Cabinet
40 mm or more
10 mm
or more
10 mm
or more
(Note 2)
40 mm
or more
(Note 1)
Servo amplifier
Wiring allowance
80 mm or more
Top
Bottom
Note 1. For 11 kW to 22 kW servo amplifiers, the clearance between the bottom and ground will be 120 mm or more.
2. For the MR-J4-500TM, the clearance between the left side and wall will be 25 mm or more.