
7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 17
7.2.3 Parameter
When using the gain switching function, always select "Manual mode (_ _ _ 3)" of "Gain adjustment mode
selection" in [Pr. PA08 Auto tuning mode]. The gain switching function cannot be used in the auto tuning
mode.
(1) Parameter for setting gain switching condition
Parameter Symbol
Name
Unit
Description
PB26
CDP
Gain switching selection
Used to select the changing condition.
PB27
CDL
Gain switching condition
[kpulse/s]
/[pulse]
/[r/min]
Used to set the changing condition values.
PB28
CDT
Gain switching time constant
[ms]
Set the filter time constant for a gain change at changing.
(a) [Pr. PB26 Gain switching function]
Used to set the gain switching condition. Select the switching condition in the first to third digits.
Gain switching selection
0: Disabled
1: Switching is enabled by control command from controller (C_CDP)
and Input device CDP (Gain switching)
2: Command frequency
3: Droop pulses
4: Servo motor speed
0
Gain switching condition
0: Gain after switching is enabled with gain switching condition or more
1: Gain after switching is enabled with gain switching condition or less
[Pr. PB26]
Gain switching time constant disabling condition selection
0: Switching time constant enabled
1: Switching time constant disabled
2: Return time constant disabled
(b) [Pr. PB27 Gain switching condition]
Set a level to switch gains with [Pr. PB27] after you select "Command frequency", "Droop pulses", or
"Servo motor speed" with the gain switching selection in [Pr. PB26 Gain switching function].
The setting unit is as follows.
Gain switching condition
Unit
Command frequency
[kpulse/s]
Droop pulses
[pulse]
Servo motor speed
[r/min]/[mm/s]
(c) [Pr. PB28 Gain switching time constant]
You can set the primary delay filter to each gain at gain switching. This parameter is used to
suppress shock given to the machine if the gain difference is large at gain switching, for example.
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...