8. TROUBLESHOOTING
8 - 6
No. Name
Detail
No.
Detail name
Stop
method
(Note 4,
5)
Alarm deactivation
Alarm reset
Communication
reset
Cycling the
power
Alarm
72.1
Load-side encoder data error 1
EDB
72.2
Load-side encoder data update error
EDB
Load-side encoder normal
communication error 2
72.3
Load-side encoder data waveform error
EDB
72
72.4
Load-side encoder non-signal error
EDB
72.5
Load-side encoder hardware error 1
EDB
72.6
Load-side encoder hardware error 2
EDB
72.9
Load-side encoder data error 2
EDB
Network module
initialization error
84.1
Network module undetected error
DB
84
84.2
Network module initialization error 1
DB
84.3
Network module initialization error 2
DB
85
Network module error
85.1
Network module error 1
SD
85.2
Network module error 2
SD
85.3
Network module error 3
SD
86
Network communication
error
86.1
Network communication error 1
SD
86.2
Network communication error 2
SD
86.3
Network communication error 3
SD
8A
USB communication time-
out error
8A.1
USB communication time-out error
SD
8E
USB communication error
8E.1
USB communication receive error
SD
8E.2
USB communication checksum error
SD
8E.3
USB communication character error
SD
8E.4
USB communication command error
SD
8E.5
USB communication data number error
SD
888
Watchdog
88._ Watchdog
DB
Note 1. Leave for about 30 minutes of cooling time after removing the cause of occurrence.
2. In some controller communication status, the alarm factor may not be removed.
3. The alarm can be canceled by setting as follows:
For the fully closed loop control: set [Pr. PE03] to "1 _ _ _".
When a linear servo motor or direct motor is used: set [Pr. PL04] to "1 _ _ _".
4. The following shows three stop methods of DB, EDB, and SD.
DB: Dynamic brake stop (For a servo amplifier without the dynamic brake, the servo motor coasts.)
EDB: Electronic dynamic brake stop (available with specified servo motors)
Refer to the following table for the specified servo motors. DB is applied as the stop method for other
than the specified servo motor.
Series
Servo
motor
HG-KR HG-KR053/HG-KR13/HG-KR23/HG-KR43
HG-MR HG-MR053/HG-MR13/HG-MR23/HG-MR43
HG-SR HG-SR51/HG-SR52
SD: Forced stop deceleration
5. This is applicable when [Pr. PA04] is set to the initial value. The stop method of SD can be changed to DB
using [Pr. PA04].
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...