4. STARTUP
4 - 12
(2) Indication list
Indication Status
Description
Initializing
System check in progress
A b
Initializing
No connection with the controller
A C
Initializing
During initial communication with the controller
A A
Initializing
standby Communication
disconnection with the controller
(Note 1) b # #
Ready-off
The ready-off signal from the controller was received.
(Note 1) d # #
Servo-on
The ready-off signal from the controller was received.
(Note 1) C # #
Servo-off
The ready-off signal from the controller was received.
(Note 1)
# #
n
Alarm occurrence
An alarm or warning occurred on the servo amplifier.
(Note 2)
* *
*
Alarm and warning
The alarm No. and the warning No. that occurred is displayed. (Refer to chapter 8.)
8 8
8
CPU error
CPU watchdog error has occurred.
(Note 1)
# #
b
.
(Note 3)
Test operation mode
JOG operation, positioning operation, program operation, output signal (DO) forced
output or motor-less operation was set.
# #
d
.
# #
C
.
Note 1. ## is displayed in hexadecimal. The following table shows the description.
## Description
00
For the last 2 digits of axis No. or
automatic setting with the controller.
01
FF
Last 2 digits of axis No.
2. ** indicates the alarm No. and the warning No.
3. Requires the MR Configurator2.
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...