5. PARAMETERS
5 - 58
5.2.5 Extension setting 2 parameters ([Pr. PE_ _ ])
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT EIP
PE01
**FCT1
Fully closed
loop function
selection 1
_ _ _ x Fully closed loop function selection
Select the fully closed loop function.
0: Always enabled
1: Switching by fully closed loop selection command from controller (C_CLD) and
Input device CLD (Fully closed loop control selection)
0h
Fully closed loop selection
Control method
Command from
controller (C_CLD)
CLD (Fully closed
loop selection)
(Note)
Off
Off
Semi closed loop control
On Off
Off
On
Fully closed loop control
On On
Note. It is always off when CLD (Fully closed loop selection) is not assigned
in [Pr. PD03] to [Pr. PD05].
To enable the setting, select "Fully closed loop control mode (_ _ 1 _)" of "operation
mode selection" in [Pr. PA01].
When "Absolute position detection system" is "Enabled (_ _ _ 1)" in [Pr. PA03],
setting "1" will trigger [AL. 37 Parameter error].
When selecting "Profile mode (_ _ _ 2)" of "control mode selection" in [Pr. PA01],
setting "1" will trigger [AL. 37 Parameter error].
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PE03
*FCT2
Fully closed
loop function
selection 2
_ _ _ x Fully closed loop control error detection function selection
0: Disabled
1: Speed deviation error detection
2: Position deviation error detection
3: Speed deviation error/position deviation error detection
Refer to table 5.11 for settings.
3h
_ _ x _ Position deviation error detection system selection
0: Continuous detection system
1: Detection system at stop (detected with command set to "0")
Refer to table 5.11 for settings.
0h
_ x _ _ For manufacturer setting
0h
x _ _ _ Fully closed loop control error reset selection
0: Reset disabled (reset by powering off/on enabled)
1: Reset enabled
0h
Table 5.11 Fully closed loop control error detection functions
Setting
value
Speed deviation
error
Position deviation error
With command
0 command
_ _ 0 0
-
-
-
_ _ 0 1
-
-
_ _ 0 2
-
_ _ 0 3
_ _ 1 0
-
-
-
_ _ 1 1
-
-
_ _ 1 2
-
-
_ _ 1 3
-
: Abnormal detection enabled -: Abnormal detection disabled
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...