1. FUNCTIONS AND CONFIGURATION
1 - 14
Model:
MR-J4-_
10TM 20TM 40TM 60TM 70TM 100TM 200TM 350TM 500TM 700TM 11KTM 15KTM 22KTM
Safety
performance
Standards
certified by CB
(Note 10)
EN ISO 13849-1 category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL3, and EN 61800-5-2
Response
performance
8 ms or less (STO input off
→
energy shut off)
(Note 3)
Test pulse input
(STO)
Test pulse interval: 1 Hz to 25 Hz
Test pulse off time: Up to 1 ms
Mean time to
dangerous failure
(MTTFd)
MTTFd
≥
100 [years] (314a)
Diagnostic
coverage (DC)
DC = Medium, 97.6 [%]
Average
probability of
dangerous failures
per hour (PFH)
PFH = 6.4 × 10
-9
[1/h]
Compliance
to global
standards
CE marking
LVD: EN 61800-5-1
EMC: EN 61800-3
MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
UL standard
UL 508C
Structure (IP rating)
Natural cooling, open (IP20)
Force cooling, open (IP20)
Force cooling, open (IP20)
(Note 4)
Close
mounting
(Note 2)
3-phase power
supply input
Possible Impossible
1-phase power
supply input
Possible Impossible
Environ
ment
Ambient
temperature
Operation 0
˚
C to 55
˚
C (non-freezing)
Storage -20
˚
C to 65
˚
C (non-freezing)
Ambient
humidity
Operation
90 %RH or less (non-condensing)
Storage
Ambience
Indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust, and dirt
Altitude
2000 m or less above sea level (Note 9)
Vibration resistance
5.9 m/s
2
, at 10 Hz to 55 Hz (directions of X, Y and Z axes)
Mass [kg]
1.0 1.4
2.1
2.3 4.0 6.2
13.4
18.2
Note 1. 0.3 A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. When closely mounting the servo amplifier, operate it at an ambient temperature of 0
˚
C to 45
˚
C or at 75% or smaller effective
load ratio.
3. Test pulse is a signal which instantaneously turns off a signal to the servo amplifier at a constant period for external circuit to
self-diagnose.
4. Except for the terminal block.
5. This value is applicable when a 3-phase power supply is used.
6. The rated current is 2.9 A when the servo amplifier is used with a UL or CSA compliant servo motor.
7. When using 1-phase 200 V AC to 240 V AC power supply, operate the servo amplifier at 75% or smaller effective load ratio.
8. For the connection example of the power circuit when a DC input is used, refer to app. 1.
9. Follow the restrictions in section 2.6 when using the servo amplifiers at altitude exceeding 1000 m and up to 2000 m above
sea level.
10. The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input
diagnosis by TOFB output is performed or not. For details, refer to the Function column of [Pr. PF18] in section 5.2.6.
11. Use an external dynamic brake for this servo amplifier. Failure to do so will cause an accident because the servo motor does
not stop immediately but coasts at emergency stop. Ensure the safety in the entire equipment.
12. The external dynamic brake cannot be used for compliance with SEMI-F47 standard. Do not assign DB (Dynamic brake
interlock) in [Pr. PD07] to [Pr. PD09]. Failure to do so will cause the servo amplifier to become servo-off when an
instantaneous power failure occurs.
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...