APPENDIX
App. - 17
The connectors described by rectangles are safely separated from the main circuits described by circles.
The connected motors will be limited as follows.
(1) HG/HF/HC/HA series servo motors (Mfg.: Mitsubishi Electric)
(2) Using a servo motor complied with IEC 60034-1 and Mitsubishi Electric encoder (OBA, OSA)
App. 4.5 Signals
App. 4.5.1 Signal
The following shows MR-J4-10TM signals as a typical example.
CN3
1
2
3
5
4
6
7
9
8
10
11
12
13
14
15
16
17
18
19
20
LSP
MO1
TPR1
TPR2
DOCOM
DICOM
LZ
LSN
MO2
EM2
LG
MBR
LBR
LA
LB
LZR
LAR
ALM
DOG
INP
TOFB2
STO2
TOFB1
STO1
STOCOM
2
CN8
1
4
3
6
5
8
7
TOFCOM
STO I/O signal
connector
App. 4.5.2 I/O device
Input device
Symbol Device
Connector
Pin
No.
EM2
Forced stop 2
CN3
20
STOCOM
Common terminal for input signals STO1/STO2
3
STO1
STO1 state input
CN8
4
STO2
STO2 state input
5
Output device
Symbol Device
Connector
Pin
No.
TOFCOM
Common terminal for monitor output signal in STO state
8
TOFB1
Monitor output signal in STO1 state
CN8
6
TOFB2
Monitor output signal in STO2 state
7
Power supply
Symbol Device
Connector
Pin
No.
DICOM
Digital I/F power supply input
5
DOCOM
Digital I/F common
CN3
3
SD Shield
Plate
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...