4. STARTUP
4 - 11
4.3.3 Status display of an axis
(1) Display sequence
Controller power on
(Network communication begins)
Ready-on
Servo-on
Ordinary operation
Controller power off
Controller power on
When alarm occurs,
its alarm code
appears.
Waiting for controller power to switch on
(Network communication)
Ready-on and servo-off
Ready-on and servo-on
(Note 1)
(Note 1)
(Note 1)
(Note 2)
When an alarm No. or warning No. is displayed
Initial data communication
with the controller
(initialization communication)
Ready-off and servo-off
Example:
Flickering
Flickering
After 0.8 s
Blank
After 0.8 s
When [AL. 50 Overload 1]
occurs at axis No. 1
Example:
Flickering
Flickering
After 0.8 s
Blank
After 0.8 s
When [AL. E1 Overload warning 1]
occurs at axis No. 1
During a non servo-off causing warning,
the decimal point on the third digit LED
shows the servo-on status.
Servo amplifier power on
System check in progress
Alarm reset or warning cleared
Note 1.
The segment of the last 2 digits shows the axis number.
Axis
No. 1
Axis
No. 2
2. For the EtherCAT, turning off the controller power in the "Operational" state triggers [AL. 86.1 Network communication error 1].